Preview

Лазерная медицина

Расширенный поиск

Стабильный беспроводной мониторинг нескольких больных при компенсации засветки из окружающей среды

https://doi.org/10.37895/2071-8004-2016-20-3-112

Аннотация

Currently, hospitals are using stand alone multi parameter monitoring system for each bed, which are bulkier and expensive to use. The prototype of stable wireless multi-patient monitor with ambient light compensation is very easy to use, hand held and wireless device with high accuracy. At present SpO2 and Heart rate are the parameters monitoring considered for proof of concept demonstration and can be extended to other parameters. The idea has been patented (patent number: 201621007087) and prototype developed is under testing phase. This gives high accurate and stable results because it compensates ambient light influencing calculations which usually disrupt the readings.

Об авторах

Rakesh Kumar Sharma
Synopsys India Pvt Ltd
Россия


Bheemsain Rao
PES University
Россия


Список литературы

1. Kazushige Ouchi, Takuji Suzuki, and Miwako Doi. Lifeminder: A wearable healthcare support system with timely instruction based on the user's context - Advanced Motion Control, 8th IEEE International Workshop on AMC. - 2004.

2. Martin T., Jovanov E., Raskovic D. Issues in wearable computing for medical monitoring applications: a case study of a wearable ECG monitoring device, in: International Symposiumon Wearable Computers ISWC2000. - Atlanta, October 2000.

3. Malan D., Fulford-Jones T.R.F., Welsh M., Moulton S. CodeBlue: an adhoc sensor network infrastructure for emergency medical care, in: Proceedings of the Mobi-Sys 2004 Workshop on Applications of MobileEmbedded Systems (WAMES2004). - Boston, MA, June, 2004. - P. 12-14.

4. MSP430FG43x Mixed-Signal Microcontrollers SLAS380D -APRIL 2004-REVISED NOVEMBER. - 2014.

5. A Single-Chip Pulsoximeter Design Using the MSP430 SLA-A274B-November 2005-Revised February 2012.

6. Nordic Semiconductor ASA. nRF24L01 product specification [R]. -2006.

7. Marinos D., Vlisidis N., Giovanis C., Leonidas F., Vassilopoulos C., Aidinis C., Pagiatakis G., Schmitt N., Klaue J., Pistner T. Passenger health monitoring applications for aircraft cabin environment. International Conference for scientific computing to ocupatational engineering, IC-SCCE Athens. - june 2008.

8. Steuer et al. System for noninvasive hematocrit monitoring. - Jan 20, 2004.


Рецензия

Для цитирования:


Rakesh Kumar Sharma , Bheemsain Rao  Стабильный беспроводной мониторинг нескольких больных при компенсации засветки из окружающей среды. Лазерная медицина. 2016;20(3):112. https://doi.org/10.37895/2071-8004-2016-20-3-112

For citation:


Rakesh Kumar Sharma , Bheemsain Rao  Stable wireless multi-patient monitoring with ambient light compensation. Laser Medicine. 2016;20(3):112. (In Russ.) https://doi.org/10.37895/2071-8004-2016-20-3-112

Просмотров: 96


Creative Commons License
Контент доступен под лицензией Creative Commons Attribution 4.0 License.


ISSN 2071-8004 (Print)
ISSN 2686-8644 (Online)