<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">goslasmed</journal-id><journal-title-group><journal-title xml:lang="ru">Лазерная медицина</journal-title><trans-title-group xml:lang="en"><trans-title>Laser Medicine</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2071-8004</issn><issn pub-type="epub">2686-8644</issn><publisher><publisher-name>Skobelkin Centre for Laser Medicine - a branch of the Federal Clinical Center for High Medical Technologies, FMBA of Russia</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.37895/2071-8004-2016-20-3-112</article-id><article-id custom-type="elpub" pub-id-type="custom">goslasmed-317</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ЛАЗЕРНАЯ И СВЕТОДИОДНАЯ МЕДИЦИНСКАЯ АППАРАТУРА</subject></subj-group></article-categories><title-group><article-title>Стабильный беспроводной мониторинг нескольких больных при компенсации засветки из окружающей среды</article-title><trans-title-group xml:lang="en"><trans-title>Stable wireless multi-patient monitoring with ambient light compensation</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Rakesh Kumar Sharma</surname></name><name name-style="western" xml:lang="en"><surname>Rakesh Kumar Sharma</surname></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Bheemsain Rao</surname></name><name name-style="western" xml:lang="en"><surname>Bheemsain Rao</surname></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru">Synopsys India Pvt Ltd<country>Россия</country></aff><aff xml:lang="en">Synopsys India Pvt Ltd<country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru">PES University<country>Россия</country></aff><aff xml:lang="en">PES University<country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2016</year></pub-date><pub-date pub-type="epub"><day>03</day><month>08</month><year>2018</year></pub-date><volume>20</volume><issue>3</issue><fpage>112</fpage><lpage>112</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Rakesh Kumar Sharma ., Bheemsain Rao ., 2018</copyright-statement><copyright-year>2018</copyright-year><copyright-holder xml:lang="ru">Rakesh Kumar Sharma ., Bheemsain Rao .</copyright-holder><copyright-holder xml:lang="en">Rakesh Kumar Sharma ., Bheemsain Rao .</copyright-holder><license license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://goslasmed.elpub.ru/jour/article/view/317">https://goslasmed.elpub.ru/jour/article/view/317</self-uri><trans-abstract xml:lang="en"><p>Currently, hospitals are using stand alone multi parameter monitoring system for each bed, which are bulkier and expensive to use. The prototype of stable wireless multi-patient monitor with ambient light compensation is very easy to use, hand held and wireless device with high accuracy. At present SpO2 and Heart rate are the parameters monitoring considered for proof of concept demonstration and can be extended to other parameters. The idea has been patented (patent number: 201621007087) and prototype developed is under testing phase. This gives high accurate and stable results because it compensates ambient light influencing calculations which usually disrupt the readings.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>patient monitor</kwd><kwd>Pulse Oximeter</kwd><kwd>Heart Rate</kwd><kwd>SpO2</kwd><kwd>light compensation</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Kazushige Ouchi, Takuji Suzuki, and Miwako Doi. Lifeminder: A wearable healthcare support system with timely instruction based on the user's context - Advanced Motion Control, 8th IEEE International Workshop on AMC. - 2004.</mixed-citation><mixed-citation xml:lang="en">Kazushige Ouchi, Takuji Suzuki, and Miwako Doi. Lifeminder: A wearable healthcare support system with timely instruction based on the user's context - Advanced Motion Control, 8th IEEE International Workshop on AMC. - 2004.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Martin T., Jovanov E., Raskovic D. Issues in wearable computing for medical monitoring applications: a case study of a wearable ECG monitoring device, in: International Symposiumon Wearable Computers ISWC2000. - Atlanta, October 2000.</mixed-citation><mixed-citation xml:lang="en">Martin T., Jovanov E., Raskovic D. Issues in wearable computing for medical monitoring applications: a case study of a wearable ECG monitoring device, in: International Symposiumon Wearable Computers ISWC2000. - Atlanta, October 2000.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Malan D., Fulford-Jones T.R.F., Welsh M., Moulton S. CodeBlue: an adhoc sensor network infrastructure for emergency medical care, in: Proceedings of the Mobi-Sys 2004 Workshop on Applications of MobileEmbedded Systems (WAMES2004). - Boston, MA, June, 2004. - P. 12-14.</mixed-citation><mixed-citation xml:lang="en">Malan D., Fulford-Jones T.R.F., Welsh M., Moulton S. CodeBlue: an adhoc sensor network infrastructure for emergency medical care, in: Proceedings of the Mobi-Sys 2004 Workshop on Applications of MobileEmbedded Systems (WAMES2004). - Boston, MA, June, 2004. - P. 12-14.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">MSP430FG43x Mixed-Signal Microcontrollers SLAS380D -APRIL 2004-REVISED NOVEMBER. - 2014.</mixed-citation><mixed-citation xml:lang="en">MSP430FG43x Mixed-Signal Microcontrollers SLAS380D -APRIL 2004-REVISED NOVEMBER. - 2014.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">A Single-Chip Pulsoximeter Design Using the MSP430 SLA-A274B-November 2005-Revised February 2012.</mixed-citation><mixed-citation xml:lang="en">A Single-Chip Pulsoximeter Design Using the MSP430 SLA-A274B-November 2005-Revised February 2012.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Nordic Semiconductor ASA. nRF24L01 product specification [R]. -2006.</mixed-citation><mixed-citation xml:lang="en">Nordic Semiconductor ASA. nRF24L01 product specification [R]. -2006.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Marinos D., Vlisidis N., Giovanis C., Leonidas F., Vassilopoulos C., Aidinis C., Pagiatakis G., Schmitt N., Klaue J., Pistner T. Passenger health monitoring applications for aircraft cabin environment. International Conference for scientific computing to ocupatational engineering, IC-SCCE Athens. - june 2008.</mixed-citation><mixed-citation xml:lang="en">Marinos D., Vlisidis N., Giovanis C., Leonidas F., Vassilopoulos C., Aidinis C., Pagiatakis G., Schmitt N., Klaue J., Pistner T. Passenger health monitoring applications for aircraft cabin environment. International Conference for scientific computing to ocupatational engineering, IC-SCCE Athens. - june 2008.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Steuer et al. System for noninvasive hematocrit monitoring. - Jan 20, 2004.</mixed-citation><mixed-citation xml:lang="en">Steuer et al. System for noninvasive hematocrit monitoring. - Jan 20, 2004.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
